Home
About Us
Products
History of Diaphragm Valves
Contact Us
Request Information
Valvulas Century De S.A. de C.V.
(en Espanol)
Call:
734.427.0340
Email:
info@centuryinstrument.com
Products
Automatic Diaphragm Valves
Manual Diaphragm Valves
Spare Parts for Diaphragm Valves
Diaphragm Relief Valves
Diaphragm Control Valves
Process Control Valves and Instrumentation Products
>
Automated Diaphragm Valves
>
Plastic Solid Diaphragm Valves
>
Polypropylene Plastic Solid
>
Socket Weld Automated Polypropylene (Solid Plastic) Diaphragm Valves (Unlined)
>
Item # 1"/44-3-E/A
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # 1"/44-3-E/A, Socket Weld Automated Polypropylene (Solid Plastic) Diaphragm Valves (Unlined)
larger image
Wide Selection
— available in a wide variety of body materials, linings and end connections. By utilizing such highly resistant linings as Saran, Polypropylene, Kynar, Tefzel, Glass, Rubber, etc., virtually any chemical service within the pressure/temperature limits of the valve can be handled safely and economically.
No Stem Leakage
— since the diaphragm isolates the fluid stream there is no need for a packing gland — no atmospheric contamination, no leakage or waste, no expensive maintenance of stem, seats or stuffing box.
Bubble-Tight Shut Off
— results when the downward thrust of the stem and compressor assembly molds the flexible diaphragm against the weir. The diaphragm will accommodate itself to rust, scale, slurry, or fibrous material.
Streamline Flow
— with minimum pressure drop because of the absence of grooves, pockets or sharp changes in direction of flow.
Cost Saving
— simple in-line maintenance. In less time than it takes to remove and replace a conventional valve, a new body diaphragm can be installed. Thus providing essentially a brand new valve at a tiny faction of the cost of a new or repaired conventional valve — all without removing the valve body from the line.
Flow Control
— the automated diaphragm valve provides an excellent means of handling the changing flow requirements in most process installations. By the addition of a positioner to the actuator, even more precise control can be achieved, especially in the handling of slurries, or viscous and fibrous materials.
Body Materials
— available in cast iron, ductile iron, carbon steel, stainless steel, Alloy-20, aluminum and bronze
Specifications
·
Diaphragm Selection
·
Standard Actuator Features
Specifications
Body Material
Polypropylene (Solid)
Temperature Range
-30 to 300
ºF
Typical Applications
Excellent chemical and abrasive resistance at elevated temperatures
Lining Options
Unlined
Material/Lining Classification
Plastic Solid
End Connection
Solid Plastic
larger image
End to End Dimension A
4 1/4
in
Valve Size [Fraction]
1
in
Valve Size [Decimal]
1.00
in
25.40
mm
Diaphragm Control Valve Options
730-RV
, Pilot Operated Controller Option
Line Pressure Conditions
1
0% P.D
100% P.D.
Services
Acetic Acid (to 60%)
Aluminum Nitrate
Ammonia, Aqu.
Ammonium Bromide
Calcium Hypoclorite
Deionized Water
Hydrochloric Acid
Plating Solutions All except Chrome
Salt Brine
Sea Water
Sodium Acetate
Sodium Chloride
Sodium Hydroxide
Sodium Hypochloride
Urea Ammonia Liquor
Water - Acid
Water - Deionized
White Liquor
Zinc Chloride
1
100% P.D. means that downstream pressure falls to 0 psig.
0% P.D. means that downstream pressure remains at, or returns to essentially the same as the upstream pressure.
Diaphragm Selection
Diaphragm Material
Ethylene Propylene EPDM
Diaphragm Material Description
Elastomeric
- built like a tire - especially compounded materials - ruggedly reinforced with fabric plies and designed to take a great deal of physical abuse. The sealing bead provides a greater sealing ability by localizing closing forces for bubble-tight shut-off.
Standard Actuator Features
Actuator Size Number
0
, Actuator Size "0"
1
, Actuator Size "1"
2
, Actuator Size "2"
2A
, Actuator Size "2A"
3
, Actuator Size "3"
4
, Actuator Size "4"
5
, Actuator Size "5"
Action of Actuator
1
(TYPE C) Air to Open - Air to Close
larger image
(TYPE H) Spring to Open - Air to Close
larger image
(TYPE HRT) Spring to Close - Air to Open
larger image
1
The choice of actuator size is determined by the line pressure through the value and the available operating air pressure. Some operating conditions call for substantial line pressure downstream when the valve closes.
After the valve closes, if the downstream pressure is less that 30 % of the upstream pressure - this condition is 100% Δ P. If the downstream pressure is 30% or more of the upstream pressure - the condition is 0% Δ P.
MORE IMAGES
·
Rubber
DOWNLOADS
Actuator Sizing and Charts - Type-C Actuators
(PDF, 609KB)
Actuator Sizing and Charts - Type-HRT Actuators
(PDF, 614KB)
Actuator Sizing and Charts - Type-H Actuators
(PDF, 606KB)
How to Size Saunders Type Valves
(PDF, 103KB)
Valve Sizing Constants
(PDF, 163KB)
Actuator Accessories
Adjustable Opening Limit Stops
Emergency Handwheel Closing Devices
more available ..
Diaphragm Relief Valves
Model 830-RV Diaphragm Relief Valves
Copyright © 2011 Century Instrument Company , All Rights Reserved
Site created by
ThomasNet Web Solutions
and powered by
Navigator Platform